  preliminary industrial environment ac-dc converters >100 watt pc series edition 4/7.99 1/5 melcher the power partners. step-down converter with single stage ac to dc conversion and pfc immunity to iec/en 61000-4-2, -3, -4, -5, -6 harmonics below iec/en 61000-3-2 no electrical isolation input to output complete solution with input and output filters input over- and undervoltage protection very high efficiency up to 95% output no load, overload and short-circuit proof output overvoltage protection thermal protection with automatic restart ambient operating temperature range ?0...71 c plug-in type for 19" rack systems with h15 connector extremely slim case (4te wide) fully enclosed very high reliability 190/230 watt ac-dc front end with pfc pc series universal ac-input range single outputs for 70 and 85 v dc loads no electrical isolation input to output safety according to iec/en 60950, ul 1950 lga c lga approval pending 164 6.5" 20 0.8" 4 te 111 4.4" 3 u summary the lpc series is a range of non isolated ac-dc convert- ers for use as power factor corrected front ends capable of delivering up to 230 watt at nominal output voltages of up to 85v. for higher power requirements, several units may be connected in parallel. the ac-dc converters are ideally adapted to mains opera- tion due to their universal input voltage range. key features are: power factor correction, low input harmonic distortion, no inrush current, low rfi, high immunity to electrical dis- turbances and high efficiency over the entire input voltage range. the outputs are no load, overload and short-circuit proof and are protected against overvoltages by means of a built- in suppressor diode. the converters are especially suited to powering melcher dc-dc converters of the p and q series which, depending on the mains input voltage level, provide the necessary electrical isolation for selv (safety extra low voltage) out- puts. the ok led displays the status of the converter and allows visual monitoring of the system at any time. the ac-dc converters are designed and built according to the international safety standards iec/en 60950, ul 1950, can/csa c22.2 no.950-95, lga , ul and cul. approvals are in progress. the converters are based on a single pcb with high power density. the thermal concept allows operation at full load up to an ambient temperature of 71 c in free air without forced cooling. if forced air cooling is provided the ambient temperature may exceed 71 c but the case temperature t c must remain below 95 c under all operating conditions. semiconductors and other heat generating components are mounted in such a way that the generated heat is transfered directly to the rugged metallic case. high effi- ciency, low heat dissipation and careful consideration of possible thermal stresses ensure no hot spots and high re- liability. a built-in temperature sensor generates an inhibit signal which disables the output if the case temperature t c exceeds 95 c. the output is automatically re-enabled when the temperature returns below this limit. a special feature of the lpc front end is the extremely slim case, just 4te wide. the modules are plug-in types fitted with an h15 connector for use in 19" rack systems according to din 41494. table of contents page summary .......................................................................... 1 type survey and key data .............................................. 2 type key and product marking ........................................ 2 page mechanical data .............................................................. 3 safety and installation instructions .................................. 4 description of options ...................................................... 5
preliminary pc series ac-dc converters >100 watt industrial environment edition 4/7.99 2/5 melcher the power partners. type survey and key data table 1: type survey nominal 1 output output input voltage efficiency type options output current power range designation voltage 47...63 hz u o nom [v] i o nom [a] p o nom [w] u i min ... u i max [v ac] h [%] 2 72 2.7 190 85...255 94 lpc 1901-7 3 -9 85 2.7 230 95...255 94 lpc 1902-7 4 d 1 no electrical isolation input to output. 2 measured at u i nom . 3 for use with melcher p units and q units based on an ac input voltage of up to 150 v. 4 for use with melcher p units based on an ac input voltage of up to 250 v. type key and product marking type key l pc 1 901 -7 d input voltage range u i 85/95...255 v ac, 47...63 hz ....................... l series ............................................................................ pc number of outputs ............................................................ 1 nominal voltage output 1 72 v ......................................................... 901 85 v ......................................................... 902 ambient temperature range t a : 25...71 c .................................................. -7 40...71 c .................................................. -9 customer specific ................................. -0...-6 option: converter ok signal ................................... d example: lpc 1901-7: power factor corrected ac-dc converter, input voltage range 85...255 v ac, non isolated out- put providing 72 v dc, 2.7 a. product marking basic type designation, applicable safety approval and recognition marks, ce mark, warnings, pin allocations of inputs and outputs, melcher patents and company logo. identification of led specific type designation, operating input voltage range, maximum input current, nominal output voltage and output cur- rent, degree of protection and pin allocations of auxiliary functions. batch no., serial no. and data code including production site, modification status and date of production.
preliminary industrial environment ac-dc converters >100 watt pc series edition 4/7.99 3/5 melcher the power partners. mechanical data dimensions in mm. tolerances 0.3 mm unless otherwise indicated. european projection note: long case, elongated by 60 mm for 220 mm rack depth, available on request. 104 0.15 65 111 20 35 127 0.15 164 0.5 8 0.5 19.8 m3; through measuring point of case temperature t c 20.32 (4 te) 13.43 100 95 5.5 led "ok" g reen 171.93 (din 41494) 09106 front plate main face rear face back plate fig. 1 case q03, weight 480 g aluminium, fully enclosed, black finish and self cooling
preliminary pc series ac-dc converters >100 watt industrial environment edition 4/7.99 4/5 melcher the power partners. safety and installation instructions connector pin allocation the connector pin allocation table defines the electrical potentials and the physical pin positions on the h15 con- nector. the protective earth pins (pins 12 and 14) present on all pc series converters are leading pins, ensuring that they make contact with the female connector first. 32 28 24 20 16 12 8 4 30 26 22 18 14 10 6 10025 fig. 2 view of male h15 connector table 2: pin allocation of the h15 connector pin no. electrical determination pin designation 4 output voltage negative vo 6 output voltage positive vo+ 8 phase p 10 neutral n 12 protective earth 1 14 protective earth 1 16 - pin not connected 18 - pin not connected 20 ok positive ok+ 2 22 ok negative ok 2 24 - pin not connected 26 output voltage positive vo+ 28 output voltage negative vo 30 output voltage positive vo+ 32 output voltage negative vo 1 leading pin (pre-connecting). 2 optional installation instructions the pc series ac-dc converters are components, in- tended exclusively for inclusion within other equipment by an industrial assembly operation or by professional install- ers. installation must strictly follow the national safety regu- lations in compliance with the enclosure, mounting, creep- age, clearance, casualty, markings and segregation requi- rements of the end-use application. important: since the pc series ac-dc converters do not provide electrical input to output isolation, their out- put circuit is a hazardous voltage primary circuit which must not be user accessible. dc-dc converters with accessible output circuits, pow- ered by a pc series ac-dc converter must provide dou- ble or reinforced insulation, based on the mains input voltage of the pc series ac-dc converter. refer to: safety of operator accessible output circuit of the h, k, m, p, q and s series data to determine safe installation if such dc-dc converters are powered by a pc series unit. connection to the system shall be made via the female con- nector h15 (see: accessories ). other installation methods may not meet the safety requirements. the ac-dc converters are provided with pins 12 and 14 ( ), which are reliably connected to the case. for safety reasons it is essential to connect at least one of these pins to the protective earth of the supply system. the p and n inputs (pins 8 and 10) are both internally fused. these fuses are designed to protect the unit in case of overcurrent and may not be able to satisfy all customer requirements. external fuses in the wiring to one or both input pins may therefore be necessary to ensure compli- ance with local requirements. ensure that a unit failure (e.g. by an internal short-circuit) does not result in a hazardous condition. important: do not open the modules, or guarantee will be invalidated. make sure that there is sufficient air flow available for con- vection cooling. this should be verified by measuring the case temperature when the unit is installed and operated in the user s application. the maximum specified case tem- perature t c max shall not be exceeded. see also: thermal considerations . caution: check for hazardous voltages before and after altering any connections. hazardous voltages may be present at the output terminals for 1 minute even after the mains input voltage has been disconnected from the unit. cleaning agents in order to avoid possible damage, any penetration of cleaning fluids is to be prevented, since the power supplies are not hermetically sealed. standards and approvals all pc series ac-dc converters correspond to class i equipment. they are ul recognized according to ul 1950, ul recog- nized for canada to can/csa c22.2 no. 950-95. lga ap- proval to iec/en 60950 standards pending. the units for: building in basic insulation between input and case based on their maximum rated input voltage operational insulation between input and output (opera- tional insulation according to the standards includes the case where only rectification and voltage/current regula- tion by diodes and transistors is provided, as is the case for pc series ac-dc converters. if the input circuit is a primary circuit, the output is a primary circuit, too.) use in a pollution degree 2 environment. the ac-dc converters are subject to manufacturing sur- veillance in accordance with the above mentioned ul, csa, en and with iso 9001 standards. protection degree condition: female connector fitted to the unit. ip 40: all units.
preliminary industrial environment ac-dc converters >100 watt pc series edition 4/7.99 5/5 melcher the power partners. isolation the electric strength test is performed as a factory test in accordance with iec/en 60950 and ul 1950 and should not be repeated in the field. melcher will not honour any guarantee claims resulting from electric strength field tests. table 4: isolation characteristic input to unit case electric required according to 1.0 kv rms strength iec/en 60950 1.4 kv dc test actual factory test 1 s 2.1 voltage ac test voltage equivalent 1.5 kv rms to actual factory test insulation resistance at 500 v dc > 300 m ? for creepage distances and clearances refer to: technical information: safety . safety of operator accessible output circuit if the output circuit of a power supply system is operator accessible, it shall be an selv circuit according to the iec/ en 60950 related safety standards. since the output circuit of a pc series ac-dc converter is a primary circuit, it must be non user accessible. in order to generate an accessible selv output circuit, a dc-dc con- verter, with double or reinforced insulation between input and output must be connected to the output of a pc series ac-dc converter. see: schematic safety concept . lpc ac-dc front end dc-dc converter with double or reinforced insulation input to output mains fuse suppressor diode selv earth connection + ~ ~ 10063 fuse earth connection fuse fuse earth connection fig. 3 schematic safety concept use input fuses and earthing of the ac-dc converter as per: installation instructions of this data sheet. use input fuses, earth connection of the dc-dc converter and suppressor diode as per: installation instructions and per table: safety concept leading to an selv output circuit of the data sheet of the corresponding dc-dc converter. leakage currents leakage currents flow due to internal leakage capacitance and rfi suppression y-capacitors. the current values are proportional to the mains voltage and nearly proportional to the mains frequency. they are specified at maximum oper- ating input voltage where phase, neutral and protective earth are correctly connected as required for class i equip- ment. table 5: leakage currents characteristic unit earth permissible according to 3.5 ma leakage iec/en 60950 current specified value at 255 v, 50 hz 1.1 1 1 leakage current of one lpc unit operating alone. this value will increase when powering dc-dc converters of the p or q series or any other load with an internal capacitance between its in- puts and earth. when lpc units are operated in parallel, the leakage current of the system will increase linearly with the number of paralleled units. refer to the: safety concept leading to an selv output cir- cuit tables of the h, k, m, p, q and s series dc-dc con- verter data in order to ensure that the output of the dc-dc converter, which is supplied by the pc series ac-dc con- verter, is an selv circuit according to iec/en 60950. it is the sole responsibility of the installer to ensure the com- pliance with the relevant and applicable safety regulations. more information is given in: technical information: safety . description of options option d converter ok signal option d indicates the status of the converter. when the in- put voltage is within the upper and lower limit and the output is above the lower limit the converter delivers an electrically isolated logic low. available hold-up time minimum 4 ms. table 3: temperature speci cations, valid for air pressure of 800...1200 hpa (800...1200 mbar) temperature standard -7 option -9 characteristics conditions min max min max unit t a ambient temperature operational 25 71 40 71 c t c case temperature 25 95 40 95 t s storage temperature not operational 40 100 55 100


▲Up To Search▲   

 
Price & Availability of LPC1901-9

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X